Posts tagged 'flocking'

Knobs, flocking and scum

Posted by on March 12th 2009 in Astrostuff, Making stuff
The skies here have been bad for observing for many weeks, and on Monday there was no sign of it getting better during the next few days, so I decided that it was high time that I serviced the scope ready for the rest of the year. I knew that I was going to have to take the thing apart completely, so it was worth doing any major work in one go, rather than faff about doing it week-by-week. The first job was the flocking of the inside of the tube. As supplied, the inside is sprayed with some sort of matt grey paint, and to be honest I've seen better paint jobs on Army Landrovers. Imagine Stevie Wonder repainting the stone-chips on your car using a paint-filled fire-extinguisher and you'll get some idea of what I'm on about. The paint does a mediocre job of cutting down on internal reflections, but it's not brilliant and if there are any scratches in it the reflected light can spoil an observing session. So, I got hold of a couple of sheets of self-adhesive black flocking "paper" from Edmund Optics and set about dismantling the scope. The mirrors were safely boxed and stashed away from all danger, and the rest of the fittings were removed, labelled and stored accordingly. The flocking operation was fiddly but there were no major problems, aside from wrestling with the incredibly tenacious adhesive when the sheet wasn't quite in the right place.  

A flocking brilliant job

  The second job was the replacement of the collimation screws for the mirrors. I get annoyed that I need three tools to do the adjustments (the primary mirror needs a hex key for three grub-screws and a cross-head screwdriver for three countersunks, the secondary needs a different hex key for three other grubscrews) so I decided to replace the lot with something a bit more user-friendly. A lot of folk go in for the expense of "Bob's Knobs" which are thumbscrews and hence require no tools, but there's a problem at the back end of a Celestron Newtonian - the "pushmi pullyu" screw-pairings on the primary cell are pitched at only 12mm, so large-headed thumbscrews would clash. Besides, they're expensive for what they are, and I'm a cheapskate, so I opted for stainless Phillips panheads. The problem was, what size to get? I emailed the scope's manufacturer with the following question: "Please can you tell me the thread sizes/specifications for the 3 sets of 3 collimation screws (6 on the primary, 3 on the secondary) on a 2007 C8N (the version with the thin-vane spider)?" and received the following reply: "Unfortunately the screws will be different because of various vendors that supply them. So we do not have specs on these. Thank you, Celestron Technical Services" Wow, that was a lot of help. Not! Whatever happened to the idea of standardisation? I had to resort to cadging some thread-gauges. M5 for the primary grubs, M4 for the secondary. A quick order to Stagonset resulted in the swift delivery of two dozen stainless screws various and change from a fiver. The six screws that I actually used (I didn't bother replacing the three cross-head countersunks) were 3-off M4 x 25mm @ 9p each and 3-off M5 x 12mm @ 12p each - simple, effective and way cheaper than posh knobs. Now the only tool required is the small Phillips screwdriver that was supplied with the scope. Sorted.  

New screws for the primary

New screws for the secondary

  Of course, using panheads instead of inset grubs for the primary meant that the rear mirror cover no longer fitted, so I ditched it and went for an open-ended setup. This is supposed to be a good thing anyway, as it allows quicker mirror-cooling and cuts down on thermal currents in the tube. The screw-holes for fixing the cover were opened out and tapped so that I could fit a set of rubber feet for the tube to stand on.  

Showing some (gl)ass!

  The last job before the rebuild was the cleaning of the mirrors. So many folk say that you needn't keep them fastidiously clean, but mine were caked with scum. They both had a bath in warm soapy water and a flush-off with distilled water before being rehoused. It was during that process that I confirmed that there was something odd about the primary mirror - the centre-marker wasn't central, as I've long suspected, as it explains why I've often struggled to get the scope collimated correctly. It needed to be fixed. I cut out a disc of paper the same size as the mirror and cut the centre out of it to make a template. Using it as a mask to protect the mirror, I gently peeled off the self-adhesive marker-ring and then stuck it back on in the right place - a full 5mm from where it had been. No wonder collimation had been a dodgy affair!

The properly-centred marker, complete with the scar where it was moved from.

  Anyway, after the rebuild was complete I did a full laser-collimation within 5 minutes and the results were better than ever. All I need now is a clear night to do a star-test and all should be well. Progress with the pier continues apace, but I'll tell you about that in a separate post.